easy to know

What is the standard wall thickness of PPR pipe?

The wall thickness of PPR pipe is not a fixed value, but is dynamically adjusted according to the pipe diameter, pressure level (S series), use (cold/hot water) and other factors.

What is the standard wall thickness of PPR pipe?

Content Quick View

1. List of wall thicknesses for all sizes of ppr pipe

Chinese Standard:GBT-18742.2-2002

TypeOD (mm)PN=1.25 (mm)PN=1.6 (mm)PN=2.0 (mm)PN=2.5 (mm)
Cold water pipe202.02.3––
Cold water pipe252.32.8––
Cold water pipe322.93.6––
Cold water pipe403.74.5––
Cold water pipe504.65.6––
Cold water pipe635.87.1––
Cold water pipe756.88.4––
Cold water pipe908.210.1––
Cold water pipe11010.012.3––
Hot water pipe20––2.83.4
Hot water pipe25––3.54.2
Hot water pipe32––4.45.4
Hot water pipe40––5.56.7
Hot water pipe50––6.98.3
Hot water pipe63––8.610.5
Hot water pipe75––10.312.3
Hot water pipe90––12.315.0
Hot water pipe110––15.1–
What is the standard wall thickness of PPR pipe?

2. Pressure Rating and S-Series Division

PPR pipes are distinguished by the S series (e.g. S5, S3.2, S2, etc.), which directly affects the wall thickness.

  • S5 series (1.25MPa): the thinnest wall thickness, such as DN20 tube wall thickness of 2.0mm, for low pressure cold water system
  • S3.2 series (2.0MPa): medium wall thickness, such as DN20 pipe wall thickness of 2.8mm, for medium pressure hot water system
  • S2 series (2.5MPa): the largest wall thickness (e.g. DN20 up to 3.4mm), but less used in the actual engineering

3. Practical application recommendations

  1. Domestic water supply:
    • Recommended for cold water pipe S5 series (wall thickness ≥ 2.9mm), such as DN20 pipe 2.3mm (1.25MPa) or 2.8mm (1.6MPa).
    • For hot water pipe, choose S3.2 or higher series, such as DN20 pipe with wall thickness ≥3.5mm.
  2. Industrial/High Pressure Scene:
    • The wall thickness should be calculated according to the pressure, for example, the wall thickness of DN50 pipe should be 6.9mm at 2.5MPa.

4. Notes

  1. Wall thickness deviation: small deviation is allowed (such as ± 0.3mm), but must meet the requirements of the standard.
  2. Material impact: PPR pipe high temperature limit of 95 ℃, long-term use of the recommended temperature ≤ 70 ℃, to avoid rupture due to over-temperature caused by insufficient wall thickness.

Conclusion

PPR pipe wall thickness should be combined with the pipe diameter, pressure level and use of a comprehensive selection of specific parameters can be referred to the national standards or specifications provided by the manufacturer’s table