PP-R Pipe Model and Size Chart

Here is a detailed list of PPR pipe specifications and dimensions, including pressure ratings, pipe series (S), nominal outer diameter (dn), nominal wall thickness (en), and common application scenarios. Common PPR pipe specifications and dimensions

PP-R-Pipe-Model-and-Size-Chart

Content Quick View

PP-R Pipe Outer diameter specification comparison table

Nominal Outer Diameter (DN)Nominal Diameter (DN)Application ScenarioWall Thickness Series (SDR/S)
20DN15Branch piping (cold water)S5/S4 (cold water)
25DN20Main/branch lines (hot/cold water)S3.2/S2.5 (hot water)
32DN25Main trunk/high-rise supplyS3.2/S2.5
40DN32High-flow supplyS2.5/S2
50DN40Industrial/municipal systemsS2 
63DN50Large-scale engineeringS2
75-160DN65-DN160Municipal/special applicationsSDR11-SDR5

Note:

  • Pipe series S: The smaller the number, the thicker the wall thickness (e.g., S2 has a thicker wall than S3.2). Cold water pipes can choose S5/S4, while hot water pipes require S3.2 or above.
  • Standard size ratio to SDR: SDR = 2S + 1 (e.g., S3.2 corresponds to SDR 7.4). The smaller the SDR, the stronger the pressure-bearing capacity. Pipe series S: The smaller the value, the thicker the wall thickness (e.g., S2 has a thicker wall than S3.2). Cold water pipes can choose S5/S4, while hot water pipes require S3.2 or above.
  • ‌Distinguishing cold and hot water pipes:Red line indicates hot water pipes (wall thickness ≥2.3mm), blue line indicates cold water pipes (wall thickness ≥1.9mm). Hot water pipes may substitute for cold water pipes in practice.
Considerations for PPR pipe installation

Construction and Selection Considerations

Pressure Matching:

  • Cold water systems:‌ Prioritize S5 or S4 series
  • Hot water systems:‌ Must select S3.2 or higher series (withstand ≤70℃)
  • High-pressure systems:‌ Use S2 series (e.g., geothermal/boiler circulation)

Thermofusion Requirements:

  • Pipes and fittings require identical S-series values to ensure consistent wall thickness
  • Heating temperature strictly controlled at 260-280℃
  • Heating time references pipe diameter (e.g., dn20 pipes: 5 seconds)

‌Low-Temperature Construction Limits:

  • Construction prohibited below 5℃. Low temperatures cause material embrittlement, compromising joint strength

Summary:

The specifications of PP-R pipes should be selected based on the purpose (cold/hot), pressure and pipe diameter. For home decoration, 20/25mm cold water pipes and 25mm hot water pipes are recommended. For industrial scenes, please refer to the S series standard customization.