easy to know

connection methods for pex-al-pex tubing

PEX-AL-PEX tubing (aluminum-plastic composite pipe) common connection method is mainly based on its aluminum-plastic composite structure characteristics, need to take into account the aluminum layer fixed and the plastic layer of the sealing. Common connection methods include: brass compression fitting connection, brass press fitting connection, and so on.

connection-methods-for-pex-al-pex-tubing Brass Compression Fitting VS Press Fittings

Content Quick View

PEX-AL-PEX PIPE | press fitting connnect (recommended for common use)

Sealed connection by means of special tubing fittings and locknuts

 

  1. Cutting the pipe: Use the special cutter to cut the end face of the PEX-AL-PEX pipe vertically to remove burrs.
  2. Inserting the tubing: Insert the tube end into the socket of the tubing fitting, making sure that the insertion depth meets the requirements (usually 3-5mm).
  3. Installation of lock nut: Put the lock nut on the outside of the tube and tighten it until the tube fitting fits the pipe tightly.
  4. Seal check: Test the pressure after connection to make sure there is no leakage.

PROS

  • Convenient installation: no special tools required, high construction efficiency.
  • Good sealing: Tubing fittings contain rubber rings with strong pull-out resistance.
  • Applicable Scenarios: Commonly used in low to medium pressure scenarios such as underfloor heating systems, solar hot water systems, etc.
Brass compression fittings with a multilayer pipe connection

PEX-AL-PEX PIPE | compression fitting connnect (recommended for common use)

Using copper or stainless steel rings as fasteners, the metal rings are pressed onto the pipe and fitting with special clamping pliers.

  1. Cut pipe and clean ports;
  2. Slip on the stainless steel sleeve and insert the fitting to the root;
  3. Press the stainless steel sleeve to the marked line (port 2.5-3 mm from the root of the socket) with clamping pliers;

PROS

  • Strong sealing and pull-out resistance, suitable for high pressure systems
  • Can be connected to metal pipes, valves and other equipment

Water quality impacts

  • High hardness water (containing calcium and magnesium ions) is prone to scaling, which adheres to the inner wall of the pipe and may affect the flow rate; chlorine ions accelerate the deterioration of plastics.

Other connections

  • Flared connection:Insert special fittings with locking rings and rubber seals into the pipe after flaring the end of the pipe, and secure the pipe by the locking ring.
  • flange connection:Installation of flanges at the end of the pipe, bolted to the metal pipe or equipment, with a sealing gasket in the center
  • Electrofusion connection (special design fittings only):Electrofusion fittings with built-in resistance wires are heated to fuse the pipe and fittings (aluminum layer compatible design is required) for special scenarios, but the matching of the pipe and fittings is highly required, and it is necessary to confirm whether the aluminum layer allows electrofusion process.

summarize

Each of these connection methods has its own advantages and disadvantages and applicable scenarios, and choosing the appropriate connection method can ensure the safe, reliable and stable operation of the piping system.